ITAC Assessment: GT0843
ITAC logo
ITAC Assessment: GT0843
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2007
Principal Product Plastic Film
NAICS 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $10
M
to 50
M
# of Employees 60
Plant Area 300,000
ft2
Annual Production 12,000,000
lb
Production Hrs. Annual 3,840
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $384,130 7,693,942
kWh
Electricity Demand $148,543 9,696
kW-mo/yr
Electricity Fees $36,902 -
Natural Gas $82,473 8,849
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $42,625 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $15,540 $2,000 $15,540
361,800
kWh
-
02 2.6231: Utilize controls to operate equipment only when needed $6,900 - $6,900
161,500
kWh
-
03 2.4314: Use synthetic lubricant $4,810 - $4,810
112,560
kWh
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,720 - $2,720
63,600
kWh
-
05 2.4133: Use most efficient type of electric motors $903 $2,882 $466
9,520
kWh
$437
-
kW-mo/yr
06 2.7142: Utilize higher efficiency lamps and/or ballasts $11,752 $24,975 $6,060
124,000
kWh
$5,692
-
kW-mo/yr
TOTAL RECOMMENDED $42,625 $29,857 $36,496
832,980
kWh
$6,129
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs