| Assessment Year | 2003 |
|---|---|
| Principal Product | GOLF CAR PARTS |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
79,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $117,216 | 3,115,707 |
kWh
|
$0.038 |
| Natural Gas | $109,509 | 20,221 |
MMBtu
|
$5.42 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,654 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,775 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1113: Reduce combustion air flow to optimum | $8,000 | $1,350 | - |
$8,000
-
MMBtu
|
|
| 02 | 2.6125: Keep equipment clean | $655 | - | - |
$655
-
MMBtu
|
|
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $696 | $1,680 |
$696
18,283
kWh
|
- | |
| 04 | 2.7132: Install timers on light switches in little used areas | $81 | $110 |
$81
2,138
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $3,266 | $11,300 |
$3,266
85,807
kWh
|
- | |
| 06 | 2.4226: Use / purchase optimum sized compressor | $2,086 | $7,250 |
$2,086
54,827
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,795 | $12,447 |
$1,795
51,583
kWh
|
- | |
| 08 | 2.4133: Use most efficient type of electric motors | $2,503 | $19,339 |
$2,503
67,418
kWh
|
- | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $536 | $5,146 |
$536
14,076
kWh
|
- | |
| 10 | 2.1111: Control pressure on steamer operations | $11,010 | $5,823 | - |
$11,010
-
MMBtu
|
|
| 11 | 2.2628: Utilize a less expensive cooling method | $8,026 | $1,500 |
$8,026
210,900
kWh
|
- | |
| TOTAL RECOMMENDED | $38,654 | $65,945 |
$18,989
505,032
kWh
|
$19,665
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,775 | $25,945 |
$3,120
83,632
kWh
|
$8,655
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs