Assessment Year | 2003 |
---|---|
Principal Product | COTTON YARN |
NAICS | 313110: Fiber, Yarn, and Thread Mills |
SIC | 2281: Yarn Spinning Mills |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
198,000
ft2
|
Annual Production | 48,400,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $826,270 | 26,673,163 |
kWh
|
$0.031 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,185 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,674 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $732 | $450 |
$732
22,219
kWh
|
- | - | - | |
02 | 2.4314: Use synthetic lubricant | $12,742 | - |
$6,505
197,392
kWh
|
$6,237
-
kW-mo/yr
|
- | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $2,064 | $948 |
$2,064
62,600
kWh
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $830 | $773 |
$830
25,179
kWh
|
- | - | - | |
05 | 3.4155: Meter waste water | $8,405 | $1,932 | - | - |
$8,405
-
Tgal
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,944 | $3,598 |
$3,944
119,671
kWh
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $164 | $1,068 |
$164
4,967
kWh
|
- | - | - | |
08 | 2.4224: Upgrade controls on compressors | $10,106 | $20,000 |
$10,106
306,600
kWh
|
- | - | - | |
09 | 2.8123: Pay utility bills on time | $3,198 | - | - | - | - | $3,198 | |
TOTAL RECOMMENDED | $42,185 | $28,769 |
$24,345
738,628
kWh
|
$6,237
-
kW-mo/yr
|
$8,405
-
Tgal
|
$3,198 | ||
TOTAL IMPLEMENTED | $23,674 | $6,837 |
$14,239
432,028
kWh
|
$6,237
-
kW-mo/yr
|
- | $3,198 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs