Assessment Year | 2002 |
---|---|
Principal Product | Tire Cord |
NAICS |
n/a
|
SIC | 2296: Tire Cord and Fabrics |
Sales Range | $10 M to 50M |
# of Employees | 248 |
Plant Area |
1,200,000
ft2
|
Annual Production | 9,000,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,884,973 | 30,130,129 |
kWh
|
$0.063 |
Natural Gas | $790,490 | 150,550 |
MMBtu
|
$5.25 |
LPG | $79,863 | 5,798 |
MMBtu
|
$13.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $649,819 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $354,391 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $167,930 | $432,000 |
$63,000
2,099,941
kWh
|
$95,424
-
kW-mo/yr
|
$9,506 | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $48,475 | $135,000 |
$27,198
877,491
kWh
|
$19,645
-
kW-mo/yr
|
- | - | $1,632 | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $30,879 | $7,800 |
$17,480
531,946
kWh
|
$13,399
-
kW-mo/yr
|
- | - | - | |
04 | 2.4156: Establish a preventative maintenance program | $12,008 | $2,600 |
$6,386
206,038
kWh
|
$5,239
-
kW-mo/yr
|
- | - | $383 | |
05 | 2.8114: Change rate schedules or other changes in utility service | $342,383 | - | - | - | - | - | $342,383 | |
06 | 2.2163: Use minimum steam operating pressure | $4,560 | - | - | - | - |
$4,560
-
MMBtu
|
- | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $13,020 | $27,376 | - | - | - |
$13,020
-
MMBtu
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $2,053 | $7,000 |
$2,053
43,376
kWh
|
- | - | - | - | |
09 | 2.4133: Use most efficient type of electric motors | $28,511 | $117,000 |
$16,120
490,621
kWh
|
$12,391
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $649,819 | $728,776 |
$132,237
4,249,413
kWh
|
$146,098
-
kW-mo/yr
|
$9,506 |
$17,580
-
MMBtu
|
$344,398 | ||
TOTAL IMPLEMENTED | $354,391 | $2,600 |
$6,386
206,038
kWh
|
$5,239
-
kW-mo/yr
|
- | - | $342,766 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs