Assessment Year | 2001 |
---|---|
Principal Product | Afaghans & Tapestry Products |
NAICS |
n/a
|
SIC | 2392: House furnishing, Except Curtains and Draperies |
Sales Range | $50 M to 100M |
# of Employees | 217 |
Plant Area |
220,000
ft2
|
Annual Production | 2,125,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $142,743 | 5,413,960 |
kWh
|
$0.026 |
Electricity Demand | $114,194 | 1,226 |
kW-mo/yr
|
$93.14 |
Electricity Fees | $28,549 | - |
|
- |
Natural Gas | $103,026 | 12,451 |
MMBtu
|
$8.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $70,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,067 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,810 | $8,370 | n/a |
$3,281
113,004
kWh
|
$1,389
-
kW-mo/yr
|
$140 | - | - |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,554 | - |
$1,737
59,844
kWh
|
$743
-
kW-mo/yr
|
$74 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,832 | $1,800 |
$4,641
159,840
kWh
|
$1,992
-
kW-mo/yr
|
$199 | - | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $4,279 | $5,900 |
$4,154
143,087
kWh
|
- | $125 | - | - | |
05 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $6,956 | $7,500 |
$5,390
185,637
kWh
|
$1,364
-
kW-mo/yr
|
$202 | - | - | |
06 | 2.2211: Use optimum temperature | $45,009 | $3,850 | - | - | - |
$15,009
-
MMBtu
|
$30,000 | |
TOTAL RECOMMENDED | $70,440 | $27,420 |
$19,203
661,412
kWh
|
$5,488
-
kW-mo/yr
|
$740 |
$15,009
-
MMBtu
|
$30,000 | ||
TOTAL IMPLEMENTED | $18,067 | $15,200 |
$14,185
488,564
kWh
|
$3,356
-
kW-mo/yr
|
$526 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs