| Assessment Year | 2001 |
|---|---|
| Principal Product | Glass Bottles |
| NAICS |
n/a
|
| SIC | 3221: Glass Containers |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
184,000
ft2
|
| Annual Production | 122,000,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $313,069 | 17,519,226 |
kWh
|
$0.018 |
| Electricity Demand | $219,425 | 29,616 |
kW-mo/yr
|
$7.41 |
| Electricity Fees | $108,747 | - |
|
- |
| Natural Gas | $790,503 | 157,495 |
MMBtu
|
$5.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $176,552 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings | Water Consumption Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2424: Use heat in flue gases to preheat products or materials | $80,000 | $125,000 | n/a |
$(-400.0)
(-22,380)
kWh
|
- | $(-30.0) |
$84,340
-
MMBtu
|
- | $(-3,910.0) | - | - |
| 02 | 4.123: Reduce defects by reducing product tipping | $18,750 | $1,500 | n/a | - | - | - | - | - | - | - | $18,750 |
| 03 | 3.4114: Replace city water with recycled water via cooling tower | $44,105 | $12,500 | n/a |
$(-675.0)
(-37,800)
kWh
|
- | - | - |
$24,028
-
Tgal
|
$(-1,300.0) |
$22,052
-
Tgal
|
- |
| 04 | 3.4116: Meter recycled water (to reduce sewer charges) | $30,490 | $8,220 | n/a | - | - | - | - |
$30,490
-
Tgal
|
- | - | - |
| 05 | 2.7261: Install timers and/or thermostats | $467 | $400 | n/a |
$437
24,446
kWh
|
- | $30 | - | - | - | - | - |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $2,740 | $900 | n/a |
$2,204
123,331
kWh
|
$356
-
kW-mo/yr
|
$180 | - | - | - | - | - |
| TOTAL RECOMMENDED | $176,552 | $148,520 |
$1,566
87,597
kWh
|
$356
-
kW-mo/yr
|
$180 |
$84,340
-
MMBtu
|
$54,518
-
Tgal
|
$(-5,210.0) |
$22,052
-
Tgal
|
$18,750 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings | Water Consumption Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs