Assessment Year | 1998 |
---|---|
Principal Product | Infant Apparel |
NAICS |
n/a
|
SIC | 2369: Girls', Children's, and Infants' Outerwear, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 420 |
Plant Area |
124,000
ft2
|
Annual Production | 12,000,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,938 | 2,338,804 |
kWh
|
$0.025 |
Electricity Demand | $116,989 | 7,839 |
kW-mo/yr
|
$14.92 |
Electricity Fees | $14,968 | - |
|
- |
Natural Gas | $3,495 | 563 |
MMBtu
|
$6.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $188,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,995 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,290 | $32,470 |
$2,572
101,993
kWh
|
$8,083
-
kW-mo/yr
|
$635 | - | - | |
02 | 2.7135: Install occupancy sensors | $2,742 | $400 |
$1,032
41,032
kWh
|
$1,555
-
kW-mo/yr
|
$155 | - | - | |
03 | 2.4226: Use / purchase optimum sized compressor | $6,471 | $7,000 |
$1,645
65,358
kWh
|
$4,460
-
kW-mo/yr
|
$366 | - | - | |
04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $3,253 | $8,000 |
$44
1,758
kWh
|
$3,025
-
kW-mo/yr
|
$184 | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $518 | $5,770 |
$130
5,275
kWh
|
$359
-
kW-mo/yr
|
$29 | - | - | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $44,011 | $239,000 |
$8,054
319,754
kWh
|
$24,504
-
kW-mo/yr
|
$1,953 | - | $9,500 | |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $6,125 | $13,500 | - | - | - | - | $6,125 | |
08 | 4.652: Replace existing equipment with more suitable substitutes | $113,944 | - | - |
$7,984
-
kW-mo/yr
|
- | $8,000 | $97,960 | |
TOTAL RECOMMENDED | $188,354 | $306,140 |
$13,477
535,170
kWh
|
$49,970
-
kW-mo/yr
|
$3,322 | $8,000 | $113,585 | ||
TOTAL IMPLEMENTED | $5,995 | $8,400 |
$1,076
42,790
kWh
|
$4,580
-
kW-mo/yr
|
$339 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs