Assessment Year | 1996 |
---|---|
Principal Product | Packaging Supplies |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 168 |
Plant Area |
170,000
ft2
|
Annual Production | 18,641,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,751 | 4,357,269 |
kWh
|
$0.024 |
Electricity Demand | $160,706 | 10,223 |
kW-mo/yr
|
$15.72 |
Electricity Fees | $13,373 | - |
|
- |
Natural Gas | $57,438 | 9,687 |
MMBtu
|
$5.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,706 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $39,485 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $4,450 | $19,650 |
$1,924
78,546
kWh
|
$2,322
-
kW-mo/yr
|
$204 | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $670 | $640 |
$294
12,016
kWh
|
$360
-
kW-mo/yr
|
$16 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $21,300 | $2,500 |
$9,119
372,216
kWh
|
$11,160
-
kW-mo/yr
|
$1,021 | - | - | |
04 | 2.2135: Repair and eliminate steam leaks | $1,390 | $900 | - | - | - |
$1,390
-
MMBtu
|
- | |
05 | 2.4224: Upgrade controls on compressors | $5,100 | $5,200 |
$5,100
208,089
kWh
|
- | - | - | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $20,711 | $16,120 |
$22,934
936,108
kWh
|
$28,079
-
kW-mo/yr
|
- |
$(-30,302.0)
-
MMBtu
|
- | |
07 | 2.3132: Recharge batteries on during off-peak demand periods | $1,060 | - | - |
$1,008
-
kW-mo/yr
|
$52 | - | - | |
08 | 3.5217: Reuse / recycle/ sell paper products | $11,025 | $4,850 | - | - | - | - |
$11,025
-
lb
|
|
TOTAL RECOMMENDED | $65,706 | $49,860 |
$39,371
1,606,975
kWh
|
$42,929
-
kW-mo/yr
|
$1,293 |
$(-28,912.0)
-
MMBtu
|
$11,025
-
lb
|
||
TOTAL IMPLEMENTED | $39,485 | $14,090 |
$14,513
592,321
kWh
|
$11,520
-
kW-mo/yr
|
$1,037 |
$1,390
-
MMBtu
|
$11,025
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs