Assessment Year 2022
Principal Product Filtration & separation equipment
NAICS 333999: All Other Miscellaneous General Purpose Machinery Manufacturing
SIC 3569: General Industrial Machinery and Equipment, Not Elsewhere
Sales Range $10
M
to 50
M
# of Employees 490
Plant Area 400,000
ft2
Annual Production 3,000,000
pieces
Production Hrs. Annual 3,970
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $367,690 6,672,450
kWh
Electricity Demand $167,876 21,256
kW-mo/yr
Electricity Fees $60,673 -
Natural Gas $365,228 29,485
MMBtu
TOTAL YEARLY COSTS $961,467
RECOMMENDED SAVINGS* $408,333 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $376,185

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $368,875 $44,510 - - $73,775 - - $295,100
02 2.4239: Eliminate or reduce compressed air usage $18,760 $4,640 $18,760
469,140
kWh
- - - - -
03 2.3212: Optimize plant power factor $10,721 $23,810 - $10,721
-
kW-mo/yr
- - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,168 $6,550 $7,168
179,191
kWh
- - - - -
05 2.4157: Establish a predictive maintenance program $2,250 $4,570 $478
11,950
kWh
$379
-
kW-mo/yr
- - $1,393 -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $250 $91 $155
3,863
kWh
$95
-
kW-mo/yr
- - - -
07 2.7134: Use photocell controls $142 $62 $95
2,365
kWh
$47
-
kW-mo/yr
- - - -
08 2.7224: Reduce space conditioning during non-working hours $137 $186 - - - $137
-
MMBtu
- -
09 2.7124: Make a practice of turning off lights when not needed $30 - $30
750
kWh
- - - - -
TOTAL RECOMMENDED $408,333 $84,419 $26,686
667,259
kWh
$11,242
-
kW-mo/yr
$73,775 $137
-
MMBtu
$1,393 $295,100
TOTAL IMPLEMENTED $376,185 $51,122 $7,263
181,556
kWh
$47
-
kW-mo/yr
$73,775 - - $295,100
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs