Assessment Year | 1994 |
---|---|
Principal Product | Air Conditioners |
NAICS |
n/a
|
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
108,000
ft2
|
Annual Production | 32,000
pieces
|
Production Hrs. Annual | 4,125
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $240,021 | 3,917,058 |
kWh
|
$0.061 |
Natural Gas | $46,178 | 7,919 |
MMBtu
|
$5.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,970 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,940 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,240 | $9,760 |
$2,240
36,635
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $780 | $1,000 |
$780
12,603
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,540 | $13,600 |
$4,540
74,150
kWh
|
- | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $5,920 | $1,700 |
$5,920
96,717
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $230 | - |
$230
3,810
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,410 | $500 |
$6,410
104,631
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $120 | $210 |
$120
2,052
kWh
|
- | |
08 | 2.3132: Recharge batteries on during off-peak demand periods | $1,790 | - |
$1,790
-
kWh
|
- | |
09 | 2.6218: Turn off equipment when not in use | $3,140 | - | - |
$3,140
-
MMBtu
|
|
10 | 2.5113: Use direct flame impingement or infrared processing for chamber type heating | $8,800 | $35,000 |
$8,800
442,556
kWh
|
- | |
TOTAL RECOMMENDED | $33,970 | $61,770 |
$30,830
773,154
kWh
|
$3,140
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,940 | $26,770 |
$21,800
326,788
kWh
|
$3,140
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs