Assessment Year 1993
Principal Product Commercial Ice Machines
NAICS
n/a
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range $50
M
to 100
M
# of Employees 210
Plant Area
n/a
Annual Production 40,000
pieces
Production Hrs. Annual 1,968
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $329,607 3,924,092
kWh
Natural Gas $47,657 8,392
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,310 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,380

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,080 $4,175 $1,080
12,896
kWh
02 2.7134: Use photocell controls $300 $200 $300
3,517
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,210 $640 $1,210
14,361
kWh
04 3.1191: Change procedures / equipment / operating conditions $1,180 $4,000 $1,180
14,068
kWh
05 2.2449: Recover heat from exhausted steam, hot air or hot water $9,230 $11,000 $9,230
476,260
kWh
06 2.7447: Install vinyl strip / high speed / air curtain doors $1,470 $2,480 $1,470
67,702
kWh
07 2.3212: Optimize plant power factor $18,870 $34,800 $18,870
132,474
kWh
08 2.4133: Use most efficient type of electric motors $520 $3,310 $520
6,155
kWh
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $230 - $230
2,638
kWh
10 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,220 $500 $1,220
14,654
kWh
TOTAL RECOMMENDED $35,310 $61,105 $35,310
744,725
kWh
TOTAL IMPLEMENTED $24,380 $42,795 $24,380
248,242
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs