ITAC Assessment: GT0494
ITAC logo
ITAC Assessment: GT0494
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product Furniture Frames
NAICS
n/a
SIC 2426: Hardwood Dimension and Flooring Mills
Sales Range $5
M
to 10
M
# of Employees 77
Plant Area
n/a
Annual Production 294,000
pieces
Production Hrs. Annual 5,635
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $212,947 2,987,104
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $14,699 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,840

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $3,762 $15,398 $3,762
52,755
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $409 $2,106 $409
5,862
kWh
03 2.7122: Disconnect ballasts $1,200 $1,315 $1,200
16,999
kWh
04 2.4133: Use most efficient type of electric motors $637 $600 $637
9,086
kWh
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $508 $200 $508
7,034
kWh
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,640 $950 $1,640
22,860
kWh
07 2.4133: Use most efficient type of electric motors $1,410 $7,410 $1,410
19,637
kWh
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,652 $1,650 $1,652
23,154
kWh
09 2.6231: Utilize controls to operate equipment only when needed $657 $1,000 $657
9,379
kWh
10 3.1191: Change procedures / equipment / operating conditions $2,824 - $2,824
39,566
kWh
TOTAL RECOMMENDED $14,699 $30,629 $14,699
206,332
kWh
TOTAL IMPLEMENTED $2,840 $2,265 $2,840
39,859
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs