| Assessment Year | 1991 |
|---|---|
| Principal Product | TRUCK BODIES |
| NAICS |
n/a
|
| SIC | 3713: Truck and Bus Bodies |
| Sales Range | n/a |
| # of Employees | 38 |
| Plant Area |
n/a
|
| Annual Production | 255
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $47,488 | 426,729 |
kWh
|
$0.11 |
| Natural Gas | $14,856 | 2,356 |
MMBtu
|
$6.31 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,235 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $77 | - |
$168
1,465
kWh
|
- | $(-91.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $139 | $417 |
$139
1,172
kWh
|
- | - | |
| 03 | 2.2437: Recover waste heat from equipment | $1,230 | $2,625 | - |
$1,230
-
MMBtu
|
- | |
| 04 | 2.7229: Air condition only space necessary | $1,540 | $930 | - |
$1,540
-
MMBtu
|
- | |
| 05 | 2.7261: Install timers and/or thermostats | $1,249 | - |
$924
8,499
kWh
|
$325
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $4,235 | $3,972 |
$1,231
11,136
kWh
|
$3,095
-
MMBtu
|
$(-91.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs