Assessment Year | 1991 |
---|---|
Principal Product | SLACKS AND SHORTS |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 440,000
pieces
|
Production Hrs. Annual | 1,960
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $51,330 | 558,910 |
kWh
|
$0.092 |
Natural Gas | $17,170 | 3,400 |
MMBtu
|
$5.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,032 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $2,738 | $3,500 | - |
$2,738
-
MMBtu
|
|
02 | 2.2135: Repair and eliminate steam leaks | $1,080 | $250 | - |
$1,080
-
MMBtu
|
|
03 | 2.2136: Install / repair insulation on steam lines | $36 | $72 | - |
$36
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,491 | $6,180 |
$2,491
27,257
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $830 | $125 |
$830
9,086
kWh
|
- | |
06 | 2.7245: Use direct air supply to exhaust hoods | $2,862 | $2,400 |
$2,477
26,964
kWh
|
$385
-
MMBtu
|
|
07 | 2.7446: Utilize sensors controlling roof and wall openings | $30 | $57 |
$30
293
kWh
|
- | |
08 | 2.7123: Keep lamps and reflectors clean | $965 | $2,160 |
$965
10,551
kWh
|
- | |
TOTAL RECOMMENDED | $11,032 | $14,744 |
$6,793
74,151
kWh
|
$4,239
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs