| Assessment Year | 1991 |
|---|---|
| Principal Product | HARDWOOD PLYWOOD |
| NAICS |
n/a
|
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $10 M to 50M |
| # of Employees | 168 |
| Plant Area |
n/a
|
| Annual Production | 75,000
thousand feet
|
| Production Hrs. Annual | 1,960
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $225,555 | 2,827,374 |
kWh
|
$0.080 |
| Natural Gas | $37,309 | 6,951 |
MMBtu
|
$5.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,153 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $377 | $120 |
$377
4,689
kWh
|
|
| 02 | 2.4131: Size electric motors for peak operating efficiency | $1,180 | $2,870 |
$1,180
14,654
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $913 | $6,780 |
$913
11,430
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $884 | $100 |
$884
11,137
kWh
|
|
| 05 | 2.4221: Install compressor air intakes in coolest locations | $799 | $500 |
$799
9,965
kWh
|
|
| TOTAL RECOMMENDED | $4,153 | $10,370 |
$4,153
51,875
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs