Assessment Year | 1991 |
---|---|
Principal Product | GRADUATION CAPS & GOWNS |
NAICS |
n/a
|
SIC | 2389: Apparel and Accessories, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 218 |
Plant Area |
n/a
|
Annual Production | 1,400,000
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $163,372 | 2,597,890 |
kWh
|
$0.063 |
Natural Gas | $4,045 | 1,753 |
MMBtu
|
$2.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,108 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,108 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,660 | $2,037 |
$23,660
376,319
kWh
|
- | |
02 | 2.6232: Install set-back timers | $1,390 | $1,365 |
$1,390
21,981
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $530 | $1,840 |
$530
8,499
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $2,609 | $9,880 |
$2,609
41,325
kWh
|
- | |
05 | 2.2135: Repair and eliminate steam leaks | $696 | $200 | - |
$696
-
MMBtu
|
|
06 | 2.2122: Install / repair insulation on condensate lines | $223 | $400 | - |
$223
-
MMBtu
|
|
TOTAL RECOMMENDED | $29,108 | $15,722 |
$28,189
448,124
kWh
|
$919
-
MMBtu
|
||
TOTAL IMPLEMENTED | $29,108 | $15,722 |
$28,189
448,124
kWh
|
$919
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs