Assessment Year | 1989 |
---|---|
Principal Product | DYED CARPET |
NAICS |
n/a
|
SIC | 2273: Carpets and Rugs |
Sales Range | $50 M to 100M |
# of Employees | 80 |
Plant Area |
n/a
|
Annual Production | 60,000
thousand feet
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $328,689 | 5,371,043 |
kWh
|
$0.061 |
Natural Gas | $381,390 | 130,769 |
MMBtu
|
$2.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,064 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,194 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $12,473 | $5,292 |
$12,473
203,693
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $877 | $187 |
$877
14,361
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,749 | $2,250 |
$2,749
44,842
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,422 | - |
$7,422
121,336
kWh
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $13,220 | $10,000 | - |
$13,220
-
MMBtu
|
|
06 | 2.2511: Insulate bare equipment | $650 | $1,385 | - |
$650
-
MMBtu
|
|
07 | 2.5123: Reduce fluid flow rates | $26,673 | $3,000 | - |
$26,673
-
MMBtu
|
|
TOTAL RECOMMENDED | $64,064 | $22,114 |
$23,521
384,232
kWh
|
$40,543
-
MMBtu
|
||
TOTAL IMPLEMENTED | $50,194 | $10,729 |
$23,521
384,232
kWh
|
$26,673
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs