| Assessment Year | 1996 |
|---|---|
| Principal Product | sheet metal enclosures |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 160 |
| Plant Area |
81,000
ft2
|
| Annual Production | 22,000,000
thousand feet
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $88,460 | 2,535,463 |
kWh
|
$0.035 |
| Electricity Demand | $23,117 | 3,340 |
kW-mo/yr
|
$6.92 |
| Electricity Fees | $606 | - |
|
- |
| Natural Gas | $52,388 | 13,915 |
MMBtu
|
$3.76 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,697 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $16,300 | $1,500 | - | - | - | - | $16,300 | |
| 02 | 2.8113: Purchase gas directly from a contract gas supplier | $11,310 | $500 | - | - | - | $11,310 | - | |
| 03 | 2.2511: Insulate bare equipment | $4,040 | $8,200 | - | - |
$4,040
-
MMBtu
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $329 | $1,013 |
$191
12,016
kWh
|
$138
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $58 | $115 |
$58
1,172
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $32,037 | $11,328 |
$249
13,188
kWh
|
$138
-
kW-mo/yr
|
$4,040
-
MMBtu
|
$11,310 | $16,300 | ||
| TOTAL IMPLEMENTED | $11,697 | $1,628 |
$249
13,188
kWh
|
$138
-
kW-mo/yr
|
- | $11,310 | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs