Assessment Year | 1988 |
---|---|
Principal Product | ALUMINA-ZIRCONIA PRODUCT |
NAICS |
n/a
|
SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 82 |
Plant Area |
n/a
|
Annual Production | 18,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,133,005 | 43,893,905 |
kWh
|
$0.049 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,232 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,402 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $3,132 | $1,995 |
$3,132
64,478
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $18,570 | - |
$18,570
378,077
kWh
|
|
03 | 2.7229: Air condition only space necessary | $830 | $320 |
$830
16,999
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $700 | $500 |
$700
14,361
kWh
|
|
TOTAL RECOMMENDED | $23,232 | $2,815 |
$23,232
473,915
kWh
|
||
TOTAL IMPLEMENTED | $22,402 | $2,495 |
$22,402
456,916
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs