| Assessment Year | 1988 |
|---|---|
| Principal Product | PUMPS & PUMP PARTS |
| NAICS |
n/a
|
| SIC | 3561: Pumps and Pumping Equipment |
| Sales Range | $1 M to 5M |
| # of Employees | 24 |
| Plant Area |
n/a
|
| Annual Production | 475
ton
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $38,724 | 403,869 |
kWh
|
$0.096 |
| Natural Gas | $8,942 | 1,828 |
MMBtu
|
$4.89 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,813 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $170 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $1,950 | $3,600 | - |
$1,950
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $170 | $259 |
$170
2,052
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $450 | - |
$450
4,982
kWh
|
- | |
| 04 | 3.4154: Eliminate leaks in water lines and valves | $558 | $20 |
$416
4,396
kWh
|
$142
-
MMBtu
|
|
| 05 | 2.7261: Install timers and/or thermostats | $660 | $350 | - |
$660
-
MMBtu
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $105 | $202 |
$105
1,172
kWh
|
- | |
| 07 | 2.8114: Change rate schedules or other changes in utility service | $1,760 | $2,640 |
$1,760
-
kWh
|
- | |
| 08 | 2.2511: Insulate bare equipment | $160 | $30 |
$110
1,172
kWh
|
$50
-
MMBtu
|
|
| TOTAL RECOMMENDED | $5,813 | $7,101 |
$3,011
13,774
kWh
|
$2,802
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $170 | $259 |
$170
2,052
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs