ITAC Assessment: GT0344
ITAC logo
ITAC Assessment: GT0344
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1988
Principal Product INJECTION MOLDINGS
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 173
Plant Area
n/a
Annual Production 7,800,000
lb
Production Hrs. Annual 7,200
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $163,654 4,364,889
kWh
Natural Gas $44,959 7,990
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,118 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $37,911 $21,000 $9,968
265,826
kWh
$27,943
-
MMBtu
02 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $2,970 $2,830 $(-402.0)
(-10,844)
kWh
$3,372
-
MMBtu
03 2.7447: Install vinyl strip / high speed / air curtain doors $1,230 $2,600 - $1,230
-
MMBtu
04 2.7212: Install or upgrade insulation on hvac distribution systems $90 $35 - $90
-
MMBtu
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $140 - $140
3,810
kWh
-
06 2.2531: Re-size charging openings or add movable cover or door $7,280 $1,200 $7,280
194,314
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $3,772 $8,751 $3,772
100,528
kWh
-
08 2.4133: Use most efficient type of electric motors $725 $5,250 $725
19,343
kWh
-
TOTAL RECOMMENDED $54,118 $41,666 $21,483
572,977
kWh
$32,635
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs