Assessment Year | 1988 |
---|---|
Principal Product | T-SHIRTS |
NAICS |
n/a
|
SIC | 2321: Men's and Boys' Shirts, Except Work Shirts |
Sales Range | $1 M to 5M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $45,548 | 579,132 |
kWh
|
$0.079 |
Natural Gas | $160 | 21 |
MMBtu
|
$7.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,576 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $90 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7442: Keep doors and windows shut when not on use | $60 | - |
$60
2,052
kWh
|
|
02 | 2.7212: Install or upgrade insulation on hvac distribution systems | $30 | $100 |
$30
293
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,400 | $13,460 |
$4,400
55,979
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $86 | $94 |
$86
1,172
kWh
|
|
TOTAL RECOMMENDED | $4,576 | $13,654 |
$4,576
59,496
kWh
|
||
TOTAL IMPLEMENTED | $90 | $100 |
$90
2,345
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs