Assessment Year | 1997 |
---|---|
Principal Product | wine |
NAICS |
n/a
|
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
12,538
ft2
|
Annual Production | 45,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $13,273 | 242,966 |
kWh
|
$0.055 |
Electricity Demand | $5,270 | 925 |
kW-mo/yr
|
$5.70 |
LPG | $2,375 | 353 |
MMBtu
|
$6.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $359 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $359 | $672 | n/a |
$224
1,172
kWh
|
$135
-
kW-mo/yr
|
TOTAL RECOMMENDED | $359 | $672 |
$224
1,172
kWh
|
$135
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs