| Assessment Year | 1987 |
|---|---|
| Principal Product | MOLDED PLASTIC COMPONENTS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 50,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $229,099 | 4,050,117 |
kWh
|
$0.057 |
| Natural Gas | $10,137 | 1,767 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,476 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,646 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $5,710 | $1,200 |
$5,710
-
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,561 | $6,000 |
$11,561
210,727
kWh
|
- | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $460 | $1,000 | - |
$460
-
MMBtu
|
|
| 04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,000 | $2,900 | - |
$1,000
-
MMBtu
|
|
| 05 | 2.2437: Recover waste heat from equipment | $1,830 | $8,000 | - |
$1,830
-
MMBtu
|
|
| 06 | 2.4133: Use most efficient type of electric motors | $845 | $5,130 |
$845
15,533
kWh
|
- | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,070 | - |
$1,070
19,343
kWh
|
- | |
| TOTAL RECOMMENDED | $22,476 | $24,230 |
$19,186
245,603
kWh
|
$3,290
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $19,646 | $13,330 |
$19,186
245,603
kWh
|
$460
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs