ITAC Assessment: GT0329
ITAC logo
ITAC Assessment: GT0329
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product CAST-IRON POTS & PANS
NAICS
n/a
SIC 3433: Heating Equipment, Except Electric and Warm Air Furnaces
Sales Range $1
M
to 5
M
# of Employees 120
Plant Area
n/a
Annual Production 10,200
ton
Production Hrs. Annual 1,870
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $332,990 4,411,196
kWh
Natural Gas $170,867 32,996
MMBtu
Coal $290,012 59,464
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $114,914 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $357

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,150 $1,000 $1,150
15,240
kWh
-
02 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $5,456 $1,000 $5,456
72,392
kWh
-
03 2.4221: Install compressor air intakes in coolest locations $756 $300 $756
9,965
kWh
-
04 2.1233: Analyze flue gas for proper air/fuel ratio $21,756 $30,000 - $21,756
-
MMBtu
05 2.2414: Use waste heat from hot flue gases to preheat $81,476 $57,000 - $81,476
-
MMBtu
06 2.2511: Insulate bare equipment $1,160 $1,500 - $1,160
-
MMBtu
07 2.7142: Utilize higher efficiency lamps and/or ballasts $357 $1,282 $357
4,689
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,803 $7,775 $2,803
37,222
kWh
-
TOTAL RECOMMENDED $114,914 $99,857 $10,522
139,508
kWh
$104,392
-
MMBtu
TOTAL IMPLEMENTED $357 $1,282 $357
4,689
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs