Assessment Year | 1987 |
---|---|
Principal Product | REINFORCED WIRE MESH |
NAICS |
n/a
|
SIC | 3496: Miscellaneous Fabricated Wire Products |
Sales Range | $5 M to 10M |
# of Employees | 38 |
Plant Area |
n/a
|
Annual Production | 20,000
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $131,204 | 1,703,986 |
kWh
|
$0.077 |
Natural Gas | $11,154 | 1,907 |
MMBtu
|
$5.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,228 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,698 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $18,200 | - |
$18,200
236,811
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,530 | $4,000 |
$1,530
19,930
kWh
|
|
03 | 2.6232: Install set-back timers | $1,500 | $800 |
$1,500
19,637
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $763 | $1,263 |
$763
9,965
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $235 | $645 |
$235
3,224
kWh
|
|
TOTAL RECOMMENDED | $22,228 | $6,708 |
$22,228
289,567
kWh
|
||
TOTAL IMPLEMENTED | $20,698 | $2,708 |
$20,698
269,637
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs