| Assessment Year | 1987 |
|---|---|
| Principal Product | RECLAIMED TEXTILE SCRAPS |
| NAICS |
n/a
|
| SIC | 2299: Textile goods, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 46 |
| Plant Area |
n/a
|
| Annual Production | 14,000,000
lb
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $261,150 | 4,000,879 |
kWh
|
$0.065 |
| Natural Gas | $11,074 | 1,876 |
MMBtu
|
$5.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,339 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,091 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $230 | $200 |
$230
3,517
kWh
|
- | |
| 02 | 2.7245: Use direct air supply to exhaust hoods | $9,270 | $13,000 |
$6,090
93,200
kWh
|
$3,180
-
MMBtu
|
|
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $481 | - |
$481
7,327
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,340 | $5,150 |
$2,340
35,756
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $1,018 | $3,783 |
$1,018
15,533
kWh
|
- | |
| TOTAL RECOMMENDED | $13,339 | $22,133 |
$10,159
155,333
kWh
|
$3,180
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $12,091 | $18,150 |
$8,911
136,283
kWh
|
$3,180
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs