| Assessment Year | 1987 |
|---|---|
| Principal Product | SPECIALTY PRINTING |
| NAICS |
n/a
|
| SIC | 2759: Commercial Printing, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $198,380 | 3,051,876 |
kWh
|
$0.065 |
| Natural Gas | $3,388 | 586 |
MMBtu
|
$5.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $29,504 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $29,504 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,760 | $62,400 |
$27,760
427,022
kWh
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $457 | $1,405 |
$457
7,034
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $630 | $740 |
$630
9,672
kWh
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $657 | $2,125 |
$657
9,965
kWh
|
|
| TOTAL RECOMMENDED | $29,504 | $66,670 |
$29,504
453,693
kWh
|
||
| TOTAL IMPLEMENTED | $29,504 | $66,670 |
$29,504
453,693
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs