| Assessment Year | 1987 |
|---|---|
| Principal Product | CARPET BACKING |
| NAICS |
n/a
|
| SIC | 2299: Textile goods, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 23 |
| Plant Area |
n/a
|
| Annual Production | 72,000,000
lb
|
| Production Hrs. Annual | 2,060
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $77,678 | 1,089,977 |
kWh
|
$0.071 |
| Natural Gas | $276 | 34 |
MMBtu
|
$8.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $2,015 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,830 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $546 | - |
$546
7,620
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $100 | $293 |
$100
1,465
kWh
|
|
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,184 | $3,615 |
$1,184
14,947
kWh
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $185 | $1,050 |
$185
2,638
kWh
|
|
| TOTAL RECOMMENDED | $2,015 | $4,958 |
$2,015
26,670
kWh
|
||
| TOTAL IMPLEMENTED | $1,830 | $3,908 |
$1,830
24,032
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs