Assessment Year | 1985 |
---|---|
Principal Product | FIRE HYDRANTS & VALVES |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 375 |
Plant Area |
n/a
|
Annual Production | 11,000
ton
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,346,817 | 32,358,148 |
kWh
|
$0.042 |
Natural Gas | $398,995 | 78,625 |
MMBtu
|
$5.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,321 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $80,787 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $58,700 | $82,000 | - |
$58,700
-
MMBtu
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $1,934 | $75 |
$1,934
46,600
kWh
|
- | |
03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,500 | $3,000 | - |
$1,500
-
MMBtu
|
|
04 | 2.2514: Cover open tanks | $1,100 | $320 |
$1,100
26,377
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $787 | $3,679 |
$787
19,050
kWh
|
- | |
06 | 2.1122: Re-size charging openings or add a movable door on equipment | $21,300 | $400 |
$21,300
512,016
kWh
|
- | |
TOTAL RECOMMENDED | $85,321 | $89,474 |
$25,121
604,043
kWh
|
$60,200
-
MMBtu
|
||
TOTAL IMPLEMENTED | $80,787 | $86,079 |
$22,087
531,066
kWh
|
$58,700
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs