| Assessment Year | 1985 |
|---|---|
| Principal Product | REFRACTORY CLAY |
| NAICS |
n/a
|
| SIC | 3255: Clay Refractories |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 125,000
ton
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,543 | 553,048 |
kWh
|
$0.12 |
| Natural Gas | $76,452 | 15,340 |
MMBtu
|
$4.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,133 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,559 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $329 | $330 |
$329
2,931
kWh
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $195 | $75 |
$195
1,758
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $970 | $500 |
$970
8,206
kWh
|
- | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $709 | - |
$709
5,862
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,330 | $640 |
$1,330
11,137
kWh
|
- | |
| 06 | 2.2511: Insulate bare equipment | $11,900 | $9,650 | - |
$11,900
-
MMBtu
|
|
| 07 | 2.2212: Use minimum safe oven ventilation | $16,700 | $1,000 | - |
$16,700
-
MMBtu
|
|
| TOTAL RECOMMENDED | $32,133 | $12,195 |
$3,533
29,894
kWh
|
$28,600
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,559 | $10,620 |
$1,659
14,068
kWh
|
$11,900
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs