| Assessment Year | 1985 | 
|---|---|
| Principal Product | REFRACTORY CLAY | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 3255: Clay Refractories | 
| Sales Range | $1 M  to 5M  | 
    
| # of Employees | 30 | 
| Plant Area | 
                             n/a 
                     | 
    
| Annual Production | 125,000
             
ton
 
         | 
    
| Production Hrs. Annual | 2,040
             
hrs
 
         | 
    
| Location (State) | Georgia | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,543 | 553,048 | 
             
kWh
 
         | 
        $0.12 | 
| Natural Gas | $76,452 | 15,340 | 
             
MMBtu
 
         | 
        $4.98 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,133 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $13,559 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | 
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $329 | $330 | 
                        $329
                                                     2,931
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $195 | $75 | 
                        $195
                                                     1,758
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $970 | $500 | 
                        $970
                                                     8,206
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $709 | - | 
                        $709
                                                     5,862
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,330 | $640 | 
                        $1,330
                                                     11,137
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 06 | 2.2511: Insulate bare equipment | $11,900 | $9,650 | - | 
                        $11,900
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 07 | 2.2212: Use minimum safe oven ventilation | $16,700 | $1,000 | - | 
                        $16,700
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| TOTAL RECOMMENDED | $32,133 | $12,195 | 
                        $3,533
                                                     29,894
                                 
                                            
kWh
 
                             | 
                                                                                
                        $28,600
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $13,559 | $10,620 | 
                        $1,659
                                                     14,068
                                 
                                            
kWh
 
                             | 
                                                                                
                        $11,900
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs