| Assessment Year | 1985 |
|---|---|
| Principal Product | SODIUM SILICATE |
| NAICS |
n/a
|
| SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 25 |
| Plant Area |
n/a
|
| Annual Production | 130,000
lb
|
| Production Hrs. Annual | 7,728
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $313,001 | 6,953,986 |
kWh
|
$0.045 |
| Natural Gas | $787,630 | 184,000 |
MMBtu
|
$4.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $59,476 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $59,476 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $944 | $617 |
$944
21,102
kWh
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $732 | $230 |
$732
16,120
kWh
|
- | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $18,500 | $75,000 | - |
$18,500
-
MMBtu
|
|
| 04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $39,300 | $25,000 | - |
$39,300
-
MMBtu
|
|
| TOTAL RECOMMENDED | $59,476 | $100,847 |
$1,676
37,222
kWh
|
$57,800
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $59,476 | $100,847 |
$1,676
37,222
kWh
|
$57,800
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs