| Assessment Year | 1985 |
|---|---|
| Principal Product | MOBILE HOMES |
| NAICS |
n/a
|
| SIC | 2451: Mobile Homes |
| Sales Range | $10 M to 50M |
| # of Employees | 170 |
| Plant Area |
n/a
|
| Annual Production | 1,000
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $38,549 | 512,016 |
kWh
|
$0.075 |
| Natural Gas | $26,368 | 4,950 |
MMBtu
|
$5.33 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,899 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,453 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Wood Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $3,300 | $3,042 |
$(-400.0)
(-5,275)
kWh
|
$3,700
-
MMBtu
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,560 | $2,000 |
$3,560
46,893
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $222 | $1,330 |
$222
2,931
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $671 | $71 |
$671
8,792
kWh
|
- | - | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,000 | $6,000 | - |
$4,000
-
MMBtu
|
- | |
| 06 | 3.6123: Burn wood by-products for heat | $14,146 | $100,000 | - |
$17,413
-
MMBtu
|
$(-3,267.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $25,899 | $112,443 |
$4,053
53,341
kWh
|
$25,113
-
MMBtu
|
$(-3,267.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,453 | $9,401 |
$4,453
58,616
kWh
|
$4,000
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Wood Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs