| Assessment Year | 1985 |
|---|---|
| Principal Product | FABRIC SHEETS |
| NAICS |
n/a
|
| SIC | 2211: Broadwoven Fabric Mills, Cotton |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
n/a
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $12,541 | 119,871 |
kWh
|
$0.10 |
| Natural Gas | $4,676 | 734 |
MMBtu
|
$6.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,224 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $614 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $594 | $158 |
$594
5,862
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $499 | $2,000 |
$499
4,689
kWh
|
- | |
| 03 | 2.7224: Reduce space conditioning during non-working hours | $38 | - | - |
$38
-
MMBtu
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $20 | $50 |
$20
293
kWh
|
- | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $73 | - |
$73
586
kWh
|
- | |
| TOTAL RECOMMENDED | $1,224 | $2,208 |
$1,186
11,430
kWh
|
$38
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $614 | $208 |
$614
6,155
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs