Assessment Year 1984
Principal Product CARPET BACKING
NAICS
n/a
SIC 2299: Textile goods, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 38
Plant Area
n/a
Annual Production 49,500
thousand feet
Production Hrs. Annual 4,000
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $49,080 934,936
kWh
LPG $133,400 21,801
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $68,537 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,776

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings LPG Savings
01 2.1332: Convert combustion equipment to burn natural gas $35,206 $60,000 - $(-67,120.0)
-
MMBtu
$102,326
-
MMBtu
02 2.5194: Redesign process $32,333 $20,000 - - $32,333
-
MMBtu
03 2.4133: Use most efficient type of electric motors $428 $592 $428
8,206
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $570 $102 $570
11,723
kWh
- -
TOTAL RECOMMENDED $68,537 $80,694 $998
19,929
kWh
$(-67,120.0)
-
MMBtu
$134,659
-
MMBtu
TOTAL IMPLEMENTED $35,776 $60,102 $570
11,723
kWh
$(-67,120.0)
-
MMBtu
$102,326
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs