| Assessment Year | 1984 |
|---|---|
| Principal Product | PLASTIC SHEET |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $1 M to 5M |
| # of Employees | 38 |
| Plant Area |
n/a
|
| Annual Production | 9,000,000
lb
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $127,101 | 2,524,912 |
kWh
|
$0.050 |
| Natural Gas | $5,014 | 787 |
MMBtu
|
$6.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,407 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,494 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7442: Keep doors and windows shut when not on use | $2,648 | $500 | - |
$2,648
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $1,006 | $967 |
$1,006
19,930
kWh
|
- | |
| 03 | 2.3191: Use demand controller or load shedder | $3,352 | $5,000 |
$3,352
-
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,561 | $127 |
$1,561
31,067
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $840 | $150 |
$840
16,706
kWh
|
- | |
| TOTAL RECOMMENDED | $9,407 | $6,744 |
$6,759
67,703
kWh
|
$2,648
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,494 | $1,617 |
$1,846
36,636
kWh
|
$2,648
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs