Assessment Year | 1983 |
---|---|
Principal Product | SOCKS |
NAICS |
n/a
|
SIC | 2252: Hosiery, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 134 |
Plant Area |
n/a
|
Annual Production | 14,000,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,242 | 1,157,386 |
kWh
|
$0.063 |
Natural Gas | $58,843 | 12,356 |
MMBtu
|
$4.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,902 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,044 | $2,500 | - |
$4,044
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,170 | $192 |
$1,170
18,464
kWh
|
- | |
03 | 2.5191: Modify dye beck | $5,192 | - | - |
$5,192
-
MMBtu
|
|
04 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $5,373 | $7,500 | - |
$5,373
-
MMBtu
|
|
05 | 2.2511: Insulate bare equipment | $829 | $574 |
$519
8,206
kWh
|
$310
-
MMBtu
|
|
06 | 2.4133: Use most efficient type of electric motors | $588 | $466 |
$588
9,379
kWh
|
- | |
07 | 2.2135: Repair and eliminate steam leaks | $176 | $40 | - |
$176
-
MMBtu
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $530 | $500 |
$530
8,499
kWh
|
- | |
TOTAL RECOMMENDED | $17,902 | $11,772 |
$2,807
44,548
kWh
|
$15,095
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs