| Assessment Year | 1982 |
|---|---|
| Principal Product | FABRICATED WINDOWS,DOORS |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
n/a
|
| Annual Production | 66,400
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $22,912 | 405,920 |
kWh
|
$0.056 |
| Natural Gas | $5,863 | 1,540 |
MMBtu
|
$3.81 |
| Fuel Oil #2 | $69,491 | 8,036 |
MMBtu
|
$8.65 |
| Other Energy | $22,747 | 2,628 |
MMBtu
|
$8.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,189 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,119 | $2,000 |
$1,119
19,930
kWh
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $2,512 | $273 |
$343
6,155
kWh
|
$2,169
-
MMBtu
|
|
| 03 | 2.7492: Use proper thickness of insulation on building envelope | $558 | $1,440 | - |
$558
-
MMBtu
|
|
| TOTAL RECOMMENDED | $4,189 | $3,713 |
$1,462
26,085
kWh
|
$2,727
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs