Assessment Year | 1998 |
---|---|
Principal Product | Commercial and Packaging Printing |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 202 |
Plant Area |
67,000
ft2
|
Annual Production | 72,622
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $126,724 | 3,851,407 |
kWh
|
$0.033 |
Electricity Demand | $65,651 | 8,676 |
kW-mo/yr
|
$7.57 |
Electricity Fees | $15,962 | - |
|
- |
Natural Gas | $4,394 | 696 |
MMBtu
|
$6.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,041 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,230 | $9,336 |
$2,778
84,115
kWh
|
$1,452
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.3212: Optimize plant power factor | $7,178 | $3,250 | - | - | $7,178 | - | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $664 | $600 |
$483
14,654
kWh
|
$181
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.2437: Recover waste heat from equipment | $1,290 | $662 |
$1,290
38,980
kWh
|
- | - | - | - | - | |
05 | 2.6218: Turn off equipment when not in use | $464 | $24 |
$464
14,068
kWh
|
- | - | - | - | - | |
06 | 3.1191: Change procedures / equipment / operating conditions | $6,945 | $3,518 | - | - | - |
$1,703
-
lb
|
$(-3,052.0) | $8,294 | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $3,470 | $4,750 | - | - | - |
$3,470
-
lb
|
- | - | |
08 | 3.2176: Increase use of automation | $7,800 | $4,900 | - | - | - | - | $7,800 | - | |
TOTAL RECOMMENDED | $32,041 | $27,040 |
$5,015
151,817
kWh
|
$1,633
-
kW-mo/yr
|
$7,178 |
$5,173
-
lb
|
$4,748 | $8,294 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs