| Assessment Year | 2005 |
|---|---|
| Principal Product | Asphalt |
| NAICS | 324121: Asphalt Paving Mixture and Block Manufacturing |
| SIC | 2951: Asphalt Paving Mixtures and Blocks |
| Sales Range | $5 M to 10M |
| # of Employees | 7 |
| Plant Area |
108,900
ft2
|
| Annual Production | 200,000
ton
|
| Production Hrs. Annual | 3,336
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $177,038 | 933,120 |
kWh
|
$0.19 |
| Natural Gas | $484,306 | 71,132 |
MMBtu
|
$6.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,016 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $43,237 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $25,577 | $100 | - | - | - | - | $25,577 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $847 | $576 |
$847
16,808
kWh
|
- | - | - | - | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,056 | $1,000 | - | - |
$8,056
-
MMBtu
|
- | - | |
| 04 | 2.2136: Install / repair insulation on steam lines | $1,779 | $244 | - | - |
$1,779
-
MMBtu
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,806 | $921 |
$1,017
9,951
kWh
|
$333
-
kW-mo/yr
|
- | $456 | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $5,040 | $4,422 |
$3,554
34,788
kWh
|
$1,486
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,055 | $1,905 |
$740
7,249
kWh
|
$226
-
kW-mo/yr
|
- | $89 | - | |
| 08 | 2.4133: Use most efficient type of electric motors | $856 | $1,449 |
$601
5,803
kWh
|
$255
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $45,016 | $10,617 |
$6,759
74,599
kWh
|
$2,300
-
kW-mo/yr
|
$9,835
-
MMBtu
|
$545 | $25,577 | ||
| TOTAL IMPLEMENTED | $43,237 | $10,373 |
$6,759
74,599
kWh
|
$2,300
-
kW-mo/yr
|
$8,056
-
MMBtu
|
$545 | $25,577 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs