Assessment Year | 1998 |
---|---|
Principal Product | Stationary and Transport Tanks |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $10 M to 50M |
# of Employees | 67 |
Plant Area |
40,744
ft2
|
Annual Production | 19,760
pieces
|
Production Hrs. Annual | 7,332
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $38,287 | 1,156,213 |
kWh
|
$0.033 |
Electricity Demand | $14,643 | 1,788 |
kW-mo/yr
|
$8.19 |
Electricity Fees | $1,544 | - |
|
- |
Natural Gas | $16,889 | 3,205 |
MMBtu
|
$5.27 |
LPG | $10,738 | 1,046 |
MMBtu
|
$10.27 |
Fuel Oil #2 | $7,222 | 732 |
MMBtu
|
$9.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,972 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,799 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,696 | $82 |
$1,410
42,790
kWh
|
$286
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $908 | $500 |
$701
21,102
kWh
|
$207
-
kW-mo/yr
|
- | - | - | - | |
03 | 4.114: Add/modify equipment to improve drying process | $1,443 | $278 | - | - | - | - | - | $1,443 | |
04 | 3.5316: Contract a wood pallet recycling company | $410 | $150 | - | - |
$410
-
lb
|
- | - | - | |
05 | 3.2121: Convert to electrostatic powder coating | $27,855 | $12,000 | - | - | - | $10,560 | - | $17,295 | |
06 | 2.8121: Apply for tax-free status for energy purchases | $578 | $30 | - | - | - | - | $578 | - | |
07 | 2.8123: Pay utility bills on time | $82 | - | - | - | - | - | $82 | - | |
TOTAL RECOMMENDED | $32,972 | $13,040 |
$2,111
63,892
kWh
|
$493
-
kW-mo/yr
|
$410
-
lb
|
$10,560 | $660 | $18,738 | ||
TOTAL IMPLEMENTED | $3,799 | $390 |
$1,410
42,790
kWh
|
$286
-
kW-mo/yr
|
- | - | $660 | $1,443 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs