| Assessment Year | 1997 |
|---|---|
| Principal Product | Metal Fabricated Products |
| NAICS |
n/a
|
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $1 M to 5M |
| # of Employees | 45 |
| Plant Area |
95,000
ft2
|
| Annual Production | 9,000
ton
|
| Production Hrs. Annual | 4,940
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $38,314 | 1,163,540 |
kWh
|
$0.033 |
| Electricity Demand | $36,648 | 4,896 |
kW-mo/yr
|
$7.49 |
| Electricity Fees | $11,779 | - |
|
- |
| Natural Gas | $9,870 | 3,653 |
MMBtu
|
$2.70 |
| LPG | $6,594 | 734 |
MMBtu
|
$8.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,350 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,656 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,439 | $2,055 |
$801
24,326
kWh
|
$638
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $327 | $280 |
$255
7,620
kWh
|
$72
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $134 | $182 |
$105
17,292
kWh
|
$29
-
kW-mo/yr
|
- | - | - | - | - | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,905 | $2,100 | - | - |
$1,905
-
MMBtu
|
- | - | - | - | |
| 05 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $2,123 | $700 | - | - | - |
$341
-
gal
|
- | - | $1,782 | |
| 06 | 3.7131: Use a rag recycle service | $227 | $750 | - | - | - | - |
$227
-
lb
|
- | - | |
| 07 | 4.515: Install shelves / racks to utilize unused space | $12,302 | $5,500 | - | - | - | - | - | $12,302 | - | |
| 08 | 2.8121: Apply for tax-free status for energy purchases | $2,893 | $360 | - | - | - | - | - | $2,893 | - | |
| TOTAL RECOMMENDED | $21,350 | $11,927 |
$1,161
49,238
kWh
|
$739
-
kW-mo/yr
|
$1,905
-
MMBtu
|
$341
-
gal
|
$227
-
lb
|
$15,195 | $1,782 | ||
| TOTAL IMPLEMENTED | $15,656 | $6,322 |
$360
24,912
kWh
|
$101
-
kW-mo/yr
|
- | - | - | $15,195 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs