| Assessment Year | 1997 |
|---|---|
| Principal Product | Plastic Bags |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
100,000
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $395,483 | 11,608,441 |
kWh
|
$0.034 |
| Electricity Demand | $180,090 | 25,404 |
kW-mo/yr
|
$7.09 |
| Electricity Fees | $12,421 | - |
|
- |
| Natural Gas | $100,160 | 31,281 |
MMBtu
|
$3.20 |
| LPG | $53,964 | 4,833 |
MMBtu
|
$11.17 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $59,219 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $49,980 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $7,041 | $1,750 | - | - | $7,041 | - | - | - | - | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $296 | $450 |
$261
7,620
kWh
|
$35
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
| 03 | 3.4116: Meter recycled water (to reduce sewer charges) | $1,298 | $1,100 | - | - | - |
$1,298
-
Tgal
|
- | - | - | - | - | |
| 04 | 3.5111: Filter and reuse hydraulic oil | $670 | - | - | - | - | - |
$670
-
gal
|
- | - | - | - | |
| 05 | 3.8142: Distill contaminated solvents for reuse | $8,273 | $7,500 |
$(-806.0)
(-23,740)
kWh
|
- | - | - | - |
$1,858
-
gal
|
$(-2,496.0) | - | $9,717 | |
| 06 | 3.1191: Change procedures / equipment / operating conditions | $41,641 | $2,315 |
$(-452.0)
(-13,189)
kWh
|
$(-147.0)
-
kW-mo/yr
|
- | - | - | - | - | $42,240 | - | |
| TOTAL RECOMMENDED | $59,219 | $13,115 |
$(-997.0)
(-29,309)
kWh
|
$(-112.0)
-
kW-mo/yr
|
$7,041 |
$1,298
-
Tgal
|
$670
-
gal
|
$1,858
-
gal
|
$(-2,496.0) | $42,240 | $9,717 | ||
| TOTAL IMPLEMENTED | $49,980 | $5,165 |
$(-452.0)
(-13,189)
kWh
|
$(-147.0)
-
kW-mo/yr
|
$7,041 |
$1,298
-
Tgal
|
- | - | - | $42,240 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs