| Assessment Year | 1996 |
|---|---|
| Principal Product | Distilled Liquor |
| NAICS |
n/a
|
| SIC | 2085: Distilled and Blended Liquors |
| Sales Range | $100 M to 500M |
| # of Employees | 200 |
| Plant Area |
225,000
ft2
|
| Annual Production | 5,475,000
pieces
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $80,579 | 2,473,623 |
kWh
|
$0.033 |
| Electricity Demand | $43,293 | 5,604 |
kW-mo/yr
|
$7.73 |
| Electricity Fees | $4,401 | - |
|
- |
| Natural Gas | $62,844 | 13,503 |
MMBtu
|
$4.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $73,775 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,041 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $616 | $11,156 |
$306
9,379
kWh
|
$310
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,358 | $9,190 |
$2,293
70,340
kWh
|
$1,065
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.3212: Optimize plant power factor | $2,545 | $2,161 | - | - | $2,545 | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $812 | $225 |
$812
24,912
kWh
|
- | - | - | - | |
| 05 | 2.2511: Insulate bare equipment | $3,067 | $683 | - | - | - |
$3,067
-
MMBtu
|
- | |
| 06 | 3.4115: Recover and reuse cooling water | $2,576 | $4,603 |
$(-6.0)
(-293)
kWh
|
$(-46.0)
-
kW-mo/yr
|
- | - |
$2,628
-
Tgal
|
|
| 07 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $60,801 | $21,060 | - | - | - |
$60,801
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $73,775 | $49,078 |
$3,405
104,338
kWh
|
$1,329
-
kW-mo/yr
|
$2,545 |
$63,868
-
MMBtu
|
$2,628
-
Tgal
|
||
| TOTAL IMPLEMENTED | $7,041 | $21,029 |
$2,599
79,719
kWh
|
$1,375
-
kW-mo/yr
|
- |
$3,067
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs