Assessment Year | 1995 |
---|---|
Principal Product | Livestock Feed |
NAICS |
n/a
|
SIC | 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
50,769
ft2
|
Annual Production | 138,000
ton
|
Production Hrs. Annual | 5,520
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,630 | 3,008,793 |
kWh
|
$0.048 |
Natural Gas | $33,995 | 15,027 |
MMBtu
|
$2.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,400 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,693 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,508 | $4,325 |
$2,508
57,737
kWh
|
- | |
02 | 2.7135: Install occupancy sensors | $570 | $400 |
$570
15,533
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $3,828 | $15,870 |
$3,828
79,719
kWh
|
- | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $1,652 | $170 |
$1,652
44,549
kWh
|
- | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $504 | $290 |
$504
13,775
kWh
|
- | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $135 | $135 | - |
$135
-
MMBtu
|
|
07 | 2.2437: Recover waste heat from equipment | $1,035 | $2,000 | - |
$1,035
-
MMBtu
|
|
08 | 2.2511: Insulate bare equipment | $168 | $263 | - |
$168
-
MMBtu
|
|
TOTAL RECOMMENDED | $10,400 | $23,453 |
$9,062
211,313
kWh
|
$1,338
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,693 | $20,900 |
$8,558
197,538
kWh
|
$135
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs