*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Fluid & Cultured Dairy Products
NAICS
n/a
SIC 2026: Fluid Milk
Sales Range $10
M
to 50
M
# of Employees 105
Plant Area 48,100
ft2
Annual Production 8,000,000
lb
Production Hrs. Annual 1,872
hrs
Location (State) South Dakota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $276,803 4,487,691
kWh
Natural Gas $61,559 17,183
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,468 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,145

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,705 $6,010 $4,705
87,046
kWh
-
02 2.4133: Use most efficient type of electric motors $6,399 $13,871 $6,399
101,407
kWh
-
03 2.4221: Install compressor air intakes in coolest locations $611 $1,000 $611
15,826
kWh
-
04 2.1213: Direct warmest air to combustion intake $716 $328 - $716
-
MMBtu
05 2.2511: Insulate bare equipment $325 $45 - $325
-
MMBtu
06 2.2511: Insulate bare equipment $395 $58 - $395
-
MMBtu
07 2.2437: Recover waste heat from equipment $10,317 $16,000 - $10,317
-
MMBtu
TOTAL RECOMMENDED $23,468 $37,312 $11,715
204,279
kWh
$11,753
-
MMBtu
TOTAL IMPLEMENTED $12,145 $20,254 $11,104
188,453
kWh
$1,041
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs