| Assessment Year | 1995 |
|---|---|
| Principal Product | Toner for copiers/printers |
| NAICS |
n/a
|
| SIC | 3861: Photographic Equipment and Supplies |
| Sales Range | $50 M to 100M |
| # of Employees | 160 |
| Plant Area |
208,163
ft2
|
| Annual Production | 2,100
ton
|
| Production Hrs. Annual | 6,720
hrs
|
| Location (State) | South Dakota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $727,784 | 15,993,552 |
kWh
|
$0.046 |
| Natural Gas | $22,612 | 7,180 |
MMBtu
|
$3.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $41,933 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,134 | $18,540 |
$4,134
88,511
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $14,228 | $44,797 |
$14,228
294,842
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,589 | $13,824 |
$6,589
134,232
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $8,795 | $4,000 |
$8,795
314,185
kWh
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $8,187 | $8,500 | - |
$8,187
-
MMBtu
|
|
| TOTAL RECOMMENDED | $41,933 | $89,661 |
$33,746
831,770
kWh
|
$8,187
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs