Assessment Year | 1995 |
---|---|
Principal Product | Skidsteer Loaders |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $5 M to 10M |
# of Employees | 170 |
Plant Area |
110,000
ft2
|
Annual Production | 3,000
pieces
|
Production Hrs. Annual | 5,252
hrs
|
Location (State) | South Dakota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,118 | 2,171,161 |
kWh
|
$0.036 |
Natural Gas | $53,272 | 9,616 |
MMBtu
|
$5.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,841 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,293 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,400 | $33,940 |
$11,400
312,427
kWh
|
- | |
02 | 2.7135: Install occupancy sensors | $72 | $182 |
$72
2,052
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $1,155 | $1,873 |
$1,155
31,653
kWh
|
- | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,389 | $16,960 | - |
$2,389
-
MMBtu
|
|
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $161 | $150 | - |
$161
-
MMBtu
|
|
06 | 2.4322: Use or replace with energy efficient substitutes | $2,371 | $20,000 |
$2,371
65,064
kWh
|
- | |
07 | 2.7313: Recycle air for heating, ventilation and air conditioning | $12,293 | $38,640 |
$(-2,209.0)
(-60,668)
kWh
|
$14,502
-
MMBtu
|
|
TOTAL RECOMMENDED | $29,841 | $111,745 |
$12,789
350,528
kWh
|
$17,052
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,293 | $38,640 |
$(-2,209.0)
(-60,668)
kWh
|
$14,502
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs