ITAC Assessment: DL0268
ITAC logo
ITAC Assessment: DL0268
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Automotive parts
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 77,000
ft2
Annual Production 100,000
units
Production Hrs. Annual 2,500
hrs
Location (State) Delaware

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $46,583 539,631
kWh
Electricity Demand $38,660 2,497
kW-mo/yr
Electricity Fees $3,489 -
Natural Gas $47,220 5,109
MMBtu
Other Gas $1,472 1
MMBtu
TOTAL YEARLY COSTS $137,424
RECOMMENDED SAVINGS* $22,523 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $1,184 - $596
6,925
kWh
$588
-
kW-mo/yr
-
02 2.7261: Install timers and/or thermostats $808 - $406
4,726
kWh
$402
-
kW-mo/yr
-
03 2.7211: Clean and maintain refrigerant condensers and towers $879 - $220
2,560
kWh
$218
-
kW-mo/yr
$441
-
MMBtu
04 2.6212: Turn off equipment during breaks, reduce operating time $1,672 - $841
9,775
kWh
$831
-
kW-mo/yr
-
05 2.2437: Recover waste heat from equipment $670 $2,000 - - $670
-
MMBtu
06 2.7261: Install timers and/or thermostats $7,041 $6,750 - - $7,041
-
MMBtu
07 2.7261: Install timers and/or thermostats $192 $280 $96
1,121
kWh
$96
-
kW-mo/yr
-
08 2.7243: Improve air circulation with destratification fans / other methods $1,003 $8,640 - - $1,003
-
MMBtu
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,463 $25,000 $2,245
26,100
kWh
$2,218
-
kW-mo/yr
-
10 2.7447: Install vinyl strip / high speed / air curtain doors $3,280 $33,000 - - $3,280
-
MMBtu
11 2.2515: Use optimum thickness insulation $1,331 $20,000 - - $1,331
-
MMBtu
TOTAL RECOMMENDED $22,523 $95,670 $4,404
51,207
kWh
$4,353
-
kW-mo/yr
$13,766
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs