Assessment Year | 2025 |
---|---|
Principal Product | Concrete components |
NAICS | 327390: Other Concrete Product Manufacturing |
SIC | 3272: Concrete Products, Except Block and Brick |
Sales Range | $50 M to 100M |
# of Employees | 130 |
Plant Area |
77,000
ft2
|
Annual Production | 19,200
ton
|
Production Hrs. Annual | 3,850
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,356 | 542,352 |
kWh
|
$0.10 |
Electricity Demand | $8,724 | 2,169 |
kW-mo/yr
|
$4.02 |
Electricity Fees | $1,968 | - |
|
- |
LPG | $32,545 | 1,789 |
MMBtu
|
$18.19 |
Fuel Oil #1 | $15,076 | 380 |
MMBtu
|
$39.69 |
TOTAL YEARLY COSTS | $114,669 | |||
RECOMMENDED SAVINGS* | $29,007 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #1 Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $2,231 | - |
$2,100
20,192
kWh
|
$131
-
kW-mo/yr
|
- | - | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $2,414 | - |
$1,661
15,974
kWh
|
$244
-
kW-mo/yr
|
$509
-
MMBtu
|
- | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,824 | - |
$1,590
15,287
kWh
|
$234
-
kW-mo/yr
|
- | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $1,180 | $1,075 |
$1,023
9,832
kWh
|
$157
-
kW-mo/yr
|
- | - | |
05 | 2.2134: Eliminate leaks in high pressure reducing stations | $386 | $1,750 |
$335
3,224
kWh
|
$51
-
kW-mo/yr
|
- | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $1,096 | $13,500 |
$950
9,130
kWh
|
$146
-
kW-mo/yr
|
- | - | |
07 | 3.5112: Reprocess spent oils on site for re-use | $1,561 | $16,500 | - | - |
$1,561
-
MMBtu
|
- | |
08 | 2.7231: Use radiant heater for spot heating | $10,284 | $6,448 | - | - |
$(-4,792.0)
-
MMBtu
|
$15,076
-
MMBtu
|
|
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,031 | $7,046 |
$6,963
66,950
kWh
|
$1,068
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $29,007 | $46,319 |
$14,622
140,589
kWh
|
$2,031
-
kW-mo/yr
|
$(-2,722.0)
-
MMBtu
|
$15,076
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #1 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs